1.We buy Power Supply no wire from a minimum quantity of 1 lb 2.Power Supply no wire refers to complete computer power supply units whose external output cables and connectors have been removed or cut short. Any brand, model, wattage, or compatible form factor meeting the Ohata standard is purchased at the corresponding grade price. 3.This recycling grade must retain its internal circuit board, transformers, copper coils, aluminum heat sinks, fan, and other major components. Empty housings, heavily dismantled units, or power supplies missing key internal materials do not qualify. 4.Recoverable value mainly comes from copper transformers and inductors, steel enclosures, aluminum heat sinks, internal circuit boards, and fan motors. Because the copper-rich external wiring is absent, this grade normally has a lower material value than a comparable complete power supply with wires. 5.Clean and intact no-wire power supplies should be separated from wired, modular, broken, burned, empty, or heavily contaminated units. Mixed grades and models may be downgraded because additional sorting and dismantling require significant staff time.
Power Supply no wire buying scrap price
1.We buy Power Supply no wire from a minimum quantity of 1 lb 2.Power Supply no wire refers to complete computer power supply units whose external output cables and connectors have been removed or cut short. Any brand, model, wattage, or compatible form factor meeting the Ohata standard is purchased at the corresponding grade price. 3.This recycling grade must retain its internal circuit board, transformers, copper coils, aluminum heat sinks, fan, and other major components. Empty housings, heavily dismantled units, or power supplies missing key internal materials do not qualify. 4.Recoverable value mainly comes from copper transformers and inductors, steel enclosures, aluminum heat sinks, internal circuit boards, and fan motors. Because the copper-rich external wiring is absent, this grade normally has a lower material value than a comparable complete power supply with wires. 5.Clean and intact no-wire power supplies should be separated from wired, modular, broken, burned, empty, or heavily contaminated units. Mixed grades and models may be downgraded because additional sorting and dismantling require significant staff time.
Buying Details of Conditions
Introduction, Construction, Components, and Recycling Value
Examples may include desktop ATX power supplies, compact SFX units, older OEM computer power supplies, workstation power supplies, and similar enclosed switch-mode power supplies. Cooler Master, Seasonic, Thermaltake, Delta, Lite-On, FSP, AcBel and other brands may all qualify. If an item satisfies the official Power Supply no wire acceptance standard, it is purchased at the corresponding grade price regardless of its original retail value.

A typical computer power supply consists of:
A steel or aluminum enclosure
An internal printed circuit board
Copper transformers and inductors
Aluminum heat sinks
Electrolytic capacitors
Power transistors, rectifiers and controller ICs
A cooling fan and metal grille
An AC input socket and power switch
Internal copper wiring
Output cables and connectors
For this grade, the external motherboard, CPU, PCIe, SATA and peripheral power cables are absent. Short insulated wire stubs may remain at the cable outlet, but complete, reusable cable bundles must not be attached.
The recycling value comes mainly from copper-bearing transformers, coils and internal conductors. Additional value is provided by the steel enclosure, aluminum heat sinks, circuit board, fan motor and small quantities of other nonferrous metals.
However, the material value of a power supply without cables is generally lower than that of an equivalent complete power supply with its original copper-rich wire harness. Output cables can contain a meaningful amount of insulated copper. When those cables are removed, the remaining unit contains less recoverable copper by total weight.
Original wattage or efficiency certification does not automatically determine recycling value. A 700-watt retail power supply without cables is not necessarily graded above a 400-watt unit in the same recycling category. Ohata evaluates the item according to the applicable scrap classification, physical completeness, contamination level and recoverable material content.
Ohata Power Supply No Wire Classification and Identification Guide
To identify the Power Supply no wire grade, inspectors should first confirm that the item is a genuine computer or electronic equipment power supply. It should normally have a recognizable metal enclosure, ventilation openings, AC input section, internal power-conversion board and transformer components.
Use the following identification procedure:
1. Confirm the basic product type
The item must be a power supply unit rather than an empty metal case, fan housing, computer chassis, battery charger shell or unrelated electrical component.
2. Check for an enclosed internal assembly
The main enclosure should still contain its internal power-supply board, transformers, coils, heat sinks and other essential components. An empty housing does not qualify.
3. Inspect the output-wire condition
The external DC output harness must be absent. This includes the primary motherboard connector and other output connectors such as CPU, PCIe, SATA and peripheral connectors.
Acceptable examples may have:
Cables cut close to the enclosure
A few short insulated wire stubs at the grommet
No usable external connector harness
No detachable modular cables included
A power supply with its full original fixed output cables belongs in a different category, such as a complete or wired power-supply grade.
4. Confirm reasonable physical integrity
Normal scratches, dust, label wear, minor surface oxidation and small dents may be acceptable. The enclosure should not be shattered, separated into several pieces or dangerously deformed.
5. Check for prohibited damage or contamination
The following conditions may cause rejection or separate downgrade treatment:
Severe fire damage or extensive carbonization
Melted insulation caused by fire
Exploded or ruptured enclosure
Large structural cracks or broken pieces
Heavy oil, mud or wet contamination
Hazardous chemicals or biological waste
Missing internal circuit board or transformers
Excessive non-power-supply attachments
Water-filled or deliberately weight-enhanced units
A mixed load containing wired units, no-wire units, empty housings and burned units must not automatically be treated entirely as clean Power Supply no wire material. It may require sorting, deduction or downgrade treatment.
Recoverable Materials, Buying Standards, and Handling
The principal recoverable material is copper. It is commonly found in the main transformer, standby transformer, inductors, electromagnetic interference filters, fan motor and internal conductors. Copper content varies by design, size, wattage and production period, but the Ohata grade is applied according to the accepted category rather than an assumed copper content for one model.

Other recoverable materials include:
Steel: Primarily from the enclosure, screws, brackets and structural parts
Aluminum: Commonly found in heat sinks attached to power semiconductors
Copper: Found in transformers, coils, chokes, wiring and fan windings
Printed circuit board material: Contains copper tracks, solder and electronic components
Brass and plated metals: May be present in terminals, switches and AC input parts
Plastics: Found in the fan, insulation, connectors and internal supports

Precious-metal content is normally limited compared with high-grade computer boards. Small quantities of gold, silver, palladium or other metals may be present in semiconductor packages, contacts and component terminations, but they should not be considered the primary value driver.

Ohata buying standards generally require the following:
The power supply must contain its internal board and major components.
The external output-wire harness must be removed or cut off.
The unit must be reasonably dry and safe to handle.
Heavy dirt, mud, grease and foreign debris must be excluded.
Burned, broken and empty units must be separated.
Batteries and unrelated electronic parts must not be mixed into the shipment.
Different power-supply grades should be sorted before delivery.
Suppliers should place the units in strong containers because steel edges and cut wires can damage lightweight bags. Avoid throwing units in a way that breaks the housing or dislodges internal parts.
Power supplies may retain dangerous electrical energy in high-voltage capacitors even after being unplugged. Suppliers should not open, drill, crush or dismantle a power supply without appropriate training and safety procedures. Short wire stubs should not be pulled from the enclosure if doing so may expose internal conductors or damage the circuit board.
For commercial loads, keeping the material dry, clean and separated improves inspection efficiency and reduces the likelihood of deductions.
Comparison and Official Ohata Classification
The easiest way to distinguish Power Supply no wire from related grades is to compare cable condition, internal completeness and physical condition.
Classification | Identification |
|---|---|
Complete power supply with wires | Original output harness and connectors remain attached |
Power Supply no wire | Internal assembly remains complete, but external output cables are removed or cut short |
Modular power supply without detachable cables | Modular sockets remain on the chassis; evaluated according to the applicable modular-power-supply category |
Empty power-supply housing | Internal board, transformer or other major components have been removed |
Broken power supply | Housing is fractured, separated or severely deformed |
Burned power supply | Extensive heat damage, melting, soot or carbonization is present |
Dirty or contaminated power supply | Heavy grease, mud, liquid, debris or hazardous contamination is present |
Mixed power-supply load | Different grades or conditions are combined without sorting and may be downgraded |
The most important distinction is that Power Supply no wire does not mean an empty enclosure. The unit should retain the internal power-conversion assembly and recoverable components. Only the external cable harness is absent.
Likewise, a unit should not be upgraded merely because it has a well-known brand, high wattage or premium efficiency certificate. Scrap grading is based on the accepted recycling condition. Conversely, a lesser-known OEM model may receive the same grade price if it satisfies all requirements.
Under the Official Ohata Classification, any power supply that contains its principal internal components, has no complete external output-wire harness, remains reasonably intact, and is free from prohibited damage or contamination may be classified as:
Ohata Power Supply no wire

All accepted brands, models, wattages and compatible form factors that meet this standard are valued according to the Power Supply no wire grade price, rather than being priced individually by retail model. Final classification remains subject to physical inspection, shipment cleanliness, internal completeness and separation from other grades.
- 1. What is todayโs price for Power Supply no wire buying?
- As of Aug 22,2026, Ohata Shoji America Inc., (Seattle, WA, United States) is purchasing Power Supply no wire buying at 0.29 (USD/lb). We provide competitive scrap prices in Seattle, Bellevue, Renton, Tukwila, Kent, SeaTac, Tacoma, Everett, and surrounding communities.
- 2. What does โPower Supply no wireโ mean?
- It refers to a computer or electronic power supply whose external DC output cables and connectors have been removed or cut short. The internal circuit board and other major components must remain inside the enclosure.
- 3. Are all brands and models purchased at the same grade price?
- Yes. Brand, wattage, production year and original retail price do not determine this recycling grade. Any qualifying unit is purchased according to the current Power Supply no wire grade price.
- 4. Can short wire stubs remain at the cable outlet?
- Yes. Short insulated wire stubs near the enclosure or rubber grommet are acceptable. However, the complete motherboard, CPU, PCIe, SATA and peripheral cable harnesses must be absent.
- 5. Does an empty power-supply housing qualify?
- No. An empty enclosure does not qualify. The unit must retain its internal circuit board, transformers, copper coils, aluminum heat sinks and other principal components.
- 6. What recoverable materials are found inside these power supplies?
- Common recoverable materials include copper from transformers and coils, steel from the enclosure, aluminum from heat sinks, circuit boards, internal wiring and copper windings from the cooling-fan motor.
- 7. Is this grade worth less than a complete power supply with wires?
- Normally, yes. Complete output cables contain recoverable insulated copper. Removing the cable harness reduces the unitโs overall copper content and may place it in the lower Power Supply no wire category.
- 8. Are modular power supplies without detachable cables included?
- Not automatically. A modular power supply has a connector panel instead of a permanently attached output harness. It may require separate classification according to Ohataโs applicable modular power-supply buying standard.
- 9. How does your company guarantee data security during recycling?
- Every data-bearing device we buy undergoes certified software data destruction or total physical shredding before any refurbishment or material resale occurs.
- 10. How does Ohata Shoji America Inc. maintain its industry standards?
- We combine 25+ years of Japanese precision recycling expertise from our parent company, Ohata Shoji Inc., with modern American e-commerce logistics.
- 11. What is a Green-Tech E-Commerce company?
- A Green-Tech E-Commerce company uses digital technology to promote environmentally responsible business practices. Ohata Shoji America Inc. combines online commerce, AI-assisted services, and electronics recycling to help recover valuable resources from surplus and end-of-life electronic equipment.
Related Items
All In One Systems with motherboard buying
Cable/DVR Box No Hard Drive buying
Cable/DVR Box With Hard Drive buying
Hard Disk Drive (HDD) Platters buying
Hard Drive Punched or Bent no Board buying
Metal cable connectors without attached wires buying
Modems Routers Buying
Plastic gold connectors (non-metal connectors) buying